4104 Warbonnet St Bid Form

Agency: City of Memphis
State: Tennessee
Level of Government: State & Local
Category:
  • 89 - Subsistence (Food)
Opps ID: NBD13246706568635789
Posted Date: Feb 8, 2019
Due Date: Feb 18, 2019
Source: Members Only
RFP Name Status Description Posted on Deadline
4104 Warbonnet St Bid Form Open Download 2019/02/04 2019/02/18 View Details

Attachment Preview

Work Order Bid (ID)
4104 Warbonnet St Memphis TN 38109-4234
WORK ORDER INFORMATION
Work Order Name: WO/1001664/1
Work Order Type: Weatherization
Audit Name: 1000557
CLIENT INFORMATION
Client ID: 1001664
Alt. Client ID: C1001683SA101
AGENCY INFORMATION
Agency: City of Memphis Division of
Housing and Community
Development
Address: 701 N Main St
Memphis TN 38107
Agency Phone: 1-901-576-7300
Agency Fax:
Email Address: paul.young@memphistn.gov
Company Name & License Number:
Contractor's Signature:
COMMENT
This is a one story house site built in 1951. The house is built on a crawlspace and is 975 sqft. The exterior is brick
on the lower 3/4 with wood on the upper 1/4 plus gables and soffits. The attic access is a hatch located in the
hallway. The home is occupide by 2 adults and has 3 bedrooms and 1 bathroom.
Client ID: 1001664
Work Order Bid (ID)
Work Order Name: WO/1001664/1
Report Run On: 2/4/2019 4:24:41 PM
THDA Weatherization Assistance Program
Page 1 of 12
Measure Vapor Barrier Needed
(Basement/Crawlspace)
Components
Comment
975 SqFt of Ground area to be covered with a 6-mil or greater plastic vapor
barrier. Crawlspace/Basement is accessed through utility room from the
outside.
All work to be performed in accordance with Tennessee Housing Development
Agency Standard Work Specifications (SWS).
Inspected
# Material/Labour
1 Health and Safety
Items
2 Labor
Other Detail
Description/Comment Unit
Basement /
crawlspace vapor
barrier
Labor
SqFt
SqFt
Estimated
Actual
Qty Unit Cost
Total Qty Unit Cost
975
975
Total
Field Notes:
Measure Sub Total
Sub Total
Client ID: 1001664
Work Order Bid (ID)
Work Order Name: WO/1001664/1
Report Run On: 2/4/2019 4:24:41 PM
THDA Weatherization Assistance Program
Page 2 of 12
Measure Seal Ducts
Components
Comment
Contractor to seal ductwork, meet or exceed target CFM25 listed below.
During post-work inspection no more than 3 registers should have pressure
pan readings greater than 1.0 Pascals. No single reading shall be greater than
3.0 Pascals. Best practice, all registers should read less than 1.0 Pascals.
Total Duct Leakage test pre-weatherization:313 CFM25
Target Duct Sealing: 117 CFM25 (Total Leakage) or 78 CFM25 (Leakage to
Outside)
General Specifications:
Liquid Mastic to be applied to seal all seams, joints, and connections in areas
where duct sealing is performed to meet target. Areas where duct insulation
must be removed must be re-insulated with R-8 insulation. Location(s) where
boots meet drywall or subfloor to be caulked or taped with UL 181 Mastic tape.
Sealing of the Return plenum shall be done using liquid Mastic. All return
seams are to be sealed with mastic, and solid material (foam board, etc.) shall
be used around edges to fill in any voids. To repair holes in duct, place flat
sheet metal over opening and secure with sheet metal screws; seams to be
sealed with Mastic paste.
All work to be performed in accordance with Tennessee Housing Development
Agency Standard Work Specifications (SWS).
Inspected
# Material/Labour
1 Miscellaneous
Supplies
Other Detail
Description/Comment Unit
Duct Sealing
Each
Estimated
Actual
Qty Unit Cost
Total Qty Unit Cost
1
Total
Field Notes:
Measure Sub Total
Sub Total
Client ID: 1001664
Work Order Bid (ID)
Work Order Name: WO/1001664/1
Report Run On: 2/4/2019 4:24:41 PM
THDA Weatherization Assistance Program
Page 3 of 12
Measure Infiltration Redctn
Components
Comment
Reduce air infiltration by 1026 cfm. It is the responsibility of the contractor to
locate areas of leakage in addition to areas detailed below. A blower door is
recommended to find and seal air leaks. Contractor must meet or exceed the
targeted reduction. No CHANGE ORDER will be issued for air sealing
achieved below the targeted reduction #.
"open” Ring,side Door, Pre-Weatherization CFM50:2001;
Target CFM50:975.
All work to be performed in accordance with Tennessee Housing Development
Agency Standard Work Specifications (SWS).
Inspected
# Material/Labour
1 Miscellaneous
Supplies
Other Detail
Description/Comment Unit
Infiltration Reduction Each
Estimated
Actual
Qty Unit Cost
Total Qty Unit Cost
1
Total
Field Notes:
Measure Sub Total
Sub Total
Measure Attic Ins. R-30
Comment
# Material/Labour
1 Insulation
2 Labor
Other Detail
Description/Comment Unit
Attic Insulation -
Blown Fiberglass - R-
30
Attic Insulation -
Blown Fiberglass - R-
30
SqFt
SqFt
Components A2
Inspected
Estimated
Actual
Qty Unit Cost
Total Qty Unit Cost
78
78
Total
Field Notes:
Measure Sub Total
Sub Total
Client ID: 1001664
Work Order Bid (ID)
Work Order Name: WO/1001664/1
Report Run On: 2/4/2019 4:24:41 PM
THDA Weatherization Assistance Program
Page 4 of 12
Measure Attic Ins. R-30
Comment
Components A1
Inspected
# Material/Labour
1 Insulation
2 Labor
3 Miscellaneous
Supplies
Other Detail
Description/Comment Unit
Attic Insulation -
Blown Fiberglass - R-
30
Attic Insulation -
Blown Fiberglass - R-
30
Added Misc Cost -
Blown Fiberglass - R-
30
SqFt
SqFt
Each
Estimated
Actual
Qty Unit Cost
Total Qty Unit Cost
897
897
1
Total
Field Notes:
Measure Sub Total
Sub Total
Client ID: 1001664
Work Order Bid (ID)
Work Order Name: WO/1001664/1
Report Run On: 2/4/2019 4:24:41 PM
THDA Weatherization Assistance Program
Page 5 of 12
This is the opportunity summary page. You are currently viewing an overview of this opportunity and a preview of the attached documentation. For more information, please visit the Publication URL Web page.

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >