Low Profile Unit Cooler Coils

Agency: State Government of Missouri
State: Missouri
Level of Government: State & Local
Category:
  • 44 - Furnace, Steam Plant, and Drying Equip, Nuclear Reactors
Opps ID: NBD13992466816221466
Posted Date: Oct 6, 2017
Due Date: Nov 1, 2017
Solicitation No: RFQ931Y18709056
Source: Members Only

Contact Information

Solicitation No: RFQ931Y18709056 from DOC - Dept of Corrections
Steven Beeson
2729 Plaza Drive Jefferson City MO, 65109 United States
Tel: 573-526-6590
Fax:
steven.beeson@doc.mo.gov


Solicitation Header Information
Duration Dates Start Date
October 06, 2017 at 2:00:00 PM CDT
October 06, 2017 at 2:00:00 PM CDT
End Date
November 01, 2017 at 2:00:00 PM CDT
November 01, 2017 at 2:00:00 PM CDT
Solicitation RFQ931Y18709056
Title Low Profile Unit Cooler Coils
Delivery Terms Free On Board Destination
Additional Delivery Information - Northeast Correctional Center 13698 Airport Road Bowling Green, MO 63334 Phone: (573) 324-9975
Description This document constitutes a Request for Quotation (RFQ) for the provision of two (2) low profile unit cooler coils for the Missouri Department of Corrections (hereinafter referred to as the A?A?A?A?A?A?DepartmentA?A?A?A?A?A?), Northeast Correctional Center (hereinafter referred to as the A?A?A?A?A?A?NECCA?A?A?A?A?A?) in accordance with the requirements and provisions as set forth herein
Payment Terms Net 45 Days
Additional Payment Information - Accounts Payable/NECC Fiscal Management Unit Missouri Department of Corrections P.O. Box 236 Jefferson City MO 65102


Solicitation Items
No. Item Code/Name Manufacturer
Name
Manufacturer
Part Number
Delivery
Address
Desired
Delivery
Date
Subtitutes
Allowed?
Multiple
Alternative Proposals
Allowed?
Qty Unit
1 [40101700]Low Profile Unit Cooler Coils 2 each
Description: Refrigerant a?? R22; Electrical Circuit a?? 208 Volt 1 Phase 60 hz; Motor Circuit a?? 5 fans 208 Volt 1 Phase 60 hz/1/47 hp.; Thermally protected at 0.6 amps each Tray Size: 38a?? x 21a?? Dimensions: L = 9a??, W = 2a??2a??, H = 6a?? on electrical end and 8a?? on drain end. 1.25a?? Mounting Flange; Coil: 2 coils on each unit: 3 passes; dimension of physical coil are H5a?? x W5a?? x L8a?? Liquid Line Size: 3/8a?? Suction Line Size: 7/8a?? Coils must be equipped with a thermal expansion valve for a medium temperature walk-in cooler. Brand Referenced: CILDZONE Evaporator Coil Model # CTA56-157 or equivalent.