Tissue Culture Chamber

Agency: St. Louis Community College
State: Montana
Level of Government: State & Local
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Opps ID: NBD15546945679547257
Posted Date: Feb 10, 2020
Due Date: Feb 25, 2020
Solicitation No: B0003920
Source: Members Only
bid number managing coordinator/buyer telephone area code product/services description closing date/time Note
B0003920 KeJuan
Torrence
539-5226 Tissue Culture Chamber Feb. 25

Attachment Preview

B0003920 NOTICE OF INTENT TO AWARD A SOLE SOURCE
CONTRACT Index Page
Page 2
-
Pages 2 to 5 -
Pages 5 to 7 -
Pages 7 to 9 -
Inde x
Summary of B0003920
1. Tissue Culture Chamber
2. Class II Type A2 Biological Safety Cabinet R-Series
3. Geneva Scientific Class II Type A2 Biological Safety Cabinet
B0003920 NOTICE OF INTENT TO AWARD A SOLE SOURCE
CONTRACT
St. Louis Community College intends to make a purchase which has been determined to qualify
as a “Sole Source” purchase. The purpose of this “Notice of Intent to Award” is to publicly
announce the college’s intent to award a Sole Source Contract for specific goods and/or services.
Any vendor who does not agree that the goods and/or services are available only from the
contractor determined to be a sole source may protest the “Notice of Intent to Award by
contacting the Purchasing Department within ten (10) calendar days of the date this Notice is
posted. Your protest must be in writing and describe the basis for the protest. Please submit
your protest via e-mail to Purchasing@stlcc.edu and include the following in the Subject line:
PROTEST OF NOTICE OF INTENT TO AWARD SOLE SOURCE CONTRACT.
Notice Date:
January 29, 2020
Response Due Date: February 10, 2020
Vendor Name:
Geneva Scientific, LLC
Product or Service: Tissue Culture Chamber: Model CU-22L
Geneva Scientific Class II Type A2 Biological Safety Cabinet R-Series:
GARBS 3F TIIA2 E
Geneva Scientific Class II Type A2 Biological Safety Cabinet:
GABS 3F TIIA2 - E
Description:
This Percival Scientific chamber was specifically designed for plant cell
culture. Its unique design of air diffuser with slow vertical airflow, fixed
lamp bank and slide-out shelves helps to eliminate condensation on Petri
Dish Lids.
1. Tissue Culture Chamber
CU-22L
Exterior Dimensions: 33.5”W x 36.6”D x 77.9”H
Interior Space:
29.1 Total cu ft
Work Area:
21.6 Total sq ft
Growing Height:
6.1” (on each of 4 tiers)
Temperature Range: 10°- 44°C lights ON (± 0.5°C)
Return to Index
Page 2 of 9
Return to Index
Airflow: The conditioned air circulate through a rear wall duct and is
picked up by a specially designed fixed air diffuser located at
the bottom of each tier. The air is then delivered vertically
upward at a slow speed through each shelf. The air diffuser
insulates shelf level experiments from the heat generated by
the underlying light fixture. This design minimizes
condensation on dish lids.
Light Intensity: 140 micromoles/m²/s
Lighting System: Each tier of shelves per compartment is lighted by
cool white fluorescent lamps properly spaced for
uniform light intensity over entire shelf. Intensity
programmable up to 140 micromoles/m²/s of light
irradiance measured @ 6” from the lamps on 2
on/off light events. Programming and control of the
lighting is done via IntellusUltra controller.
Airflow/Circulation: Conditioned air circulates through a rear wall
duct and is picked up by a specialty designed
fixed air duffuser located at the bottom of each
tier (air is then delivered vertically upward at a
slow speed through each shelf). Air diffuser
insulates shelf level experiments from heat
generated by underlying light fixture (this design
minimizes condensation on dish lids)
Cabinet Construction: Interior constructed on 22-gauge electro-zinc
plated steel. Exterior constructed of 18-gauge
exterior electro-zinc plated steel. Welded seams
and joints on outer and inner shells. Inner shell
supported by non-compressing/non-thermal
conducting material locking inner liner in place
without a metal-to-metal bond to outer case.
Chamber is completely self-contained. Overall
wall thickness is 2”. One 1 ¼” diameter access
port on R.H. wall (one per compartment).
Chamber floor equipped with floor drain and
hose assembly. Contains caster assembly and
adjustable leveling legs to compensate for floor
unevenness in the lab.
Insulation: Woodless construction using CFC free insulation (overall
wall thickness is 2”, ample insulation for maintenance of
stated temperature range)
Page 3 of 9
Return to Index
Doors: each door opening 29.2” x 27.8” providing full access to
chamber interior (magnetic gasket provides a tight seal to door
frame)
Interior Space: Total 29.1 cu. ft. with work area of 21.6sq. ft.
provided on two shelves per compartment.
Shelving: Two tiers per compartment of white epoxy coated steel
wire shelving (each shelf is 27”D x 28.8W). Shelves side in
and out easily on stainless steel rail assemblies. Maximum
growing height is 6”.
Finish: Interior and exterior painted with high reflective,
environmentally friendly, high temperature baked white
powder coating.
Refrigeration: Twin condensing unit (this continuous running
condensing unit ensures precise temperature control by
alternating cycling refrigerant and hot gas to coil; this
also prolongs life of compressor, and eliminates risk of
ice buildup in coil). Solenoid valves have extended
stem for quiet and long life operation. Ceiling mounted
evaporator coils incorporate dual air circulation fans in
aluminum housing (heat rejection to ambient in
standard chamber = 5000 BTU/hr).
Convenience Receptacles: One 115/1/60 convenience receptacle
provided inside each compartment.
Controller: NEW IntellusUltra
Single control system providing 24 hour chamber
monitoring and control of all programmed variables
such as temperature.
Also controls lighting, humidity & CO2 when these
options are purchased.
Step and Ramp mode
500 total programs steps over 50 total programs
16 total programmable light/event outputs
Deviation alarms & light lifetime alarms
4 Program Modes: Manual, Diurnal, Program, &
Non Circadian
3 daytime and 3 nighttime temperature offsets
On-board diagnostics, ambient temperature
monitoring, and power failure event logging
Alarm Display/Audible Buzzer
Dual experiment protection with primary limit and
independent secondary limit
Page 4 of 9
Warranty: Two (2) years parts and labor
H12: Ultrasonic Humidifier & Dehumidifier with Advanced RH
Sensor
Q23+: Open loop dimmable lighting control with independent
control.
2. Class II Type A2 Biological Safety Cabinet R-Series:
GARBS-3F-TIIA2-E
External Dimensions:
40.7”W x 29.6”D x 54.7”H
Internal Work Zone:
36”W x 22.8”D x 26”H
Usable Work Area:
4.5sqft
Tested Opening:
8”
Average Inflow Velocity:
0.53 m/s (105 fpm)
Average Downflow Velocity: 0.30 m/s (60 fpm)
Air Volume:
Inflow:
208 cfm
Downflow: 325 cfm
Exhaust: 208 cfm
ULPA Filter: Typical efficiency > 99.999% for particle size between
0.1 to 0.3 microns per IEST-RP-CC001.3
Sound Emission: NSF/ANSI 49: 57.5 dBA
Light Intensity: 1983 Lux (184 foot candles)
Cabinet Main Body: 0.05” 18 gauge electrogalvanized steel with
Isocide oven-baked epoxy-polyester powder
coating
Cabinet Work Zone: 0.06” 16 gauge 304 stainless steel, 4B finish
Cabinet Side Walls: 0.06” 16 gauge 304 stainless steel, 4B finish
Electrical: 110-130V, AC, 60Hz, 1 phase
Features:
One (1) GFCI Outlet
One (1) Service Valve
UV Light
Includes
Adjustable Stand:
Adjustable Height with leveling feet or casters
(please choose when ordering)
Return to Index