J044--FY24: HAYS-CLEVELAND BOILER CONTROL SYSTEM REPAIR
Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
---|---|
State: | Florida |
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159048713758729 |
Posted Date: | Apr 17, 2024 |
Due Date: | Apr 30, 2024 |
Solicitation No: | 36C24824Q0861 |
Source: | Members Only |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Updated)
- All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
- Updated Published Date: Apr 17, 2024 01:17 pm EDT
- Original Published Date: Apr 16, 2024 09:25 pm EDT
- Updated Response Date: Apr 30, 2024 02:00 pm EDT
- Original Response Date: Apr 30, 2024 02:00 pm EDT
- Inactive Policy: Manual
- Updated Inactive Date: Jun 29, 2024
- Original Inactive Date: Jun 29, 2024
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: J044 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FURNACE, STEAM PLANT, AND DRYING EQUIPMENT; NUCLEAR REACTORS
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
Department of Veterans Affairs Orlando VA Healthcare Systems Orlando , FL 32827USA
The Hays Universal Programmable Automation Controller (UPAC) provides an operator interface for each boiler control, steam header pressure control loop, deaerator tank and condensate tank level controls, feedwater pump sequencer, condensate transfer pump sequencer, and various plant-wide flow and pressure monitoring. The boiler plant workstation is supported by a Supervisory Control and Data Acquisition (SCADA) General Electric (GE) Cimplicity based graphical SCADA software package.
After a site survey, it is determined that the Plant Master control panel containing the six control functions listed above is considered a single-point failure that will shut the plant down upon loss of power to the control panel, ceasing all steam generation. Separating the various subsystems such as the tank level controls, and pump controls, and returning the operator interface to the individual boilers, will result in a sensible and secure system that cannot be shut down by a single failure. The feedwater pump sequencer in the plant master is not being utilized, and pumps are turned on manually by the operator with the Manual / Off / Auto selector switches on the plant master panel.
NCO 8 anticipates awarding a Firm Fixed Priced purchase order for a one-time service repair. This procurement is being conducted in accordance with FAR 13.106-1(b)(1)(i), Soliciting from a single source. The applicable North American Industry Classification System (NAICS) Code is 238220 Plumbing, Heating, and Air-Conditioning Contractors, with a small business size standard of $19.0 Million.
This Notice of Intent is not a request for competitive quotes. No solicitation documents are available; however, Contractors are encouraged to join us on Microsoft Team on April 23, 2024, from 11:00 AM to 12:00 PM for discussions by dialing +1 872-701-0185, phone conference ID: 185389336# or emailing Contract Specialist Jesus M. Carrillo no later than 2:00 PM April 19, 2024, for a meeting invite on April 22, 2024. If a firm believes it can meet the requirements it must furnish information about its services, as well as references from other customers. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Submit responses to Contract Specialist, Jesus M. Carrillo, jesus.carrillo@va.gov, and  Contracting Officer rohan.mckenzie@va.gov no later than 2:00 PM, EST April 30, 2024.
Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. If no responses are received, NCO 8 will proceed with the sole source negotiation with Venergy Group, LLC.
- 8875 HIDDEN RIVER PARKWAY
- TAMPA , FL 33637
- USA
- Rohan McKenzie
- Rohan.Mckenzie@va.gov
- Phone Number 407-631-8720
- Apr 17, 2024 01:17 pm EDTPresolicitation (Updated)
- Apr 16, 2024 09:25 pm EDT Presolicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.