Janey Bochart Replacement OSS

Agency: HEALTH AND HUMAN SERVICES, DEPARTMENT OF
State: Washington
Level of Government: Federal
Category:
  • Y - Construction of Structures and Facilities
Opps ID: NBD00159250757396163
Posted Date: Mar 27, 2024
Due Date: Apr 22, 2024
Solicitation No: 75H70124Q00022
Source: Members Only
Follow
Janey Bochart Replacement OSS
Active
Contract Opportunity
Notice ID
75H70124Q00022
Related Notice
75H70124Q00022
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
INDIAN HEALTH SERVICE
Office
DIV OF ENGINEERING SVCS - SEATTLE
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Original Published Date: Mar 27, 2024 11:11 am CDT
  • Original Date Offers Due: Apr 22, 2024 02:00 pm CDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: May 07, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Y1NZ - CONSTRUCTION OF OTHER UTILITIES
  • NAICS Code:
    • 237110 - Water and Sewer Line and Related Structures Construction
  • Place of Performance:
    Longview , WA 98632
    USA
Description

This project is for the installation of an individual advanced treatment septic system on fee land in Cowlitz County, WA. For the septic system the contractor shall install 4” solid sewer pipe, an underground double sweep cleanout, a NuWater advanced Treatment Unit (ATU) 3-Chamber Tank, or Equivalent, rated for 360 gallons/day, a 1,500-gallon 2-chamber pump tank with pump (Orenco PF3005, ½ HP, or Equivalent), risers, headworks, and controls, 1.25” PVC Sch 40 of transport line and manifold (approximately 84 linear feet), and a pressure distribution system drainfield with trenches (approximately 900 SF) with monitoring wells, inspection ports, caps, and orifices per design. The contractor shall also pump out and abandon the existing septic tank and drainfield. Work shall be performed according to the SOW, site drawing, technical specifications, and Washington Water Resource Department (WWRD) standards, rules and regulations. Further investigation of the site is the responsibility of the contractor. Any permits are the responsibility of the contractor.


Attachments/Links
Contact Information
Contracting Office Address
  • 2201 6TH AVENUE MAIL STOP RX-24
  • SEATTLE , WA 98121
  • USA
Primary Point of Contact
Secondary Point of Contact
History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >