Water Controllers for USACE Locks and Dams

Agency:
State: Minnesota
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159511213190162
Posted Date: Nov 21, 2023
Due Date: Dec 15, 2023
Source: Members Only
Follow
Water Controllers for USACE Locks and Dams
Active
Contract Opportunity
Notice ID
W912ES23Q0099
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
USACE
Sub Command
MVD
Office
W07V ENDIST ST PAUL
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Updated Published Date: Nov 21, 2023 07:34 am CST
  • Original Published Date: Sep 25, 2023 03:04 pm CDT
  • Updated Date Offers Due: Dec 15, 2023 03:00 pm CST
  • Original Date Offers Due: Oct 13, 2023 03:00 pm CDT
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: Dec 30, 2023
  • Original Inactive Date: Oct 28, 2023
  • Initiative:
    • None
Classification View Changes
  • Original Set Aside:
  • Product Service Code: J046 - MAINT/REPAIR/REBUILD OF EQUIPMENT- WATER PURIFICATION AND SEWAGE TREATMENT EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Saint Paul , MN 55110
    USA
Description View Changes

The Contractor shall provide five (5) custom programed Stager Controllers for the well-water filtration systems that are installed at the following Locks and Dams: LD2 (Hastings, MN), LD5 (Minnesota City, MN), LD5A (Fountain City, WI), LD7 (La Crescent, MN), LD9 (Eastman, WI). These systems were originally designed, built and installed by Robert Hill Company in St Louis Park, MN.



The resulting contract is for the replacement of the controller units only. The U.S. Army Corps of Engineers (USACE) has no preference for brand, make, or model of the controllers provided they comply with the performance requirements listed below and integrate into the currently working system. Additional parts may be required to insure the system and new components are compatible. No adjustment in contract price will be made for failure to ensure component compatibility.



The systems at all five sites incorporate four tanks on a balanced manifold. Iron in the water is oxidized then filtered through backwashing filters. Oxidation is accomplished with dissolved potassium permanganate injected into the water stream via a chemical feed pump. The chemical feed pump is wired to operate with the well pump.



The filters are four 30” diameter steel tanks. The filter beds are composed of manganese greensand, a manganese coated glauconite capped with anthracite filter coal. The four in-line tanks filter, until a set volume is treated, or a set period of time has passed. The filters are then taken off-line and back-washed individually. Following backwash, the filters are then returned to service. Backwash is provided by the remaining tanks on-line, so there is no contamination in the lower distributor or lower layers of the filter bed.



Stager Controller






  • Complete Stager Module

  • UL (or nationally accredited test lab) listed components.

  • 12-month parts and labor warranty.

  • Components and spare parts must be available within 10 days.

  • Electronic copies of schematics, program data and ladder diagrams must be provided prior to award for evaulation.

  • Programs start, stop and cycle time of back flush cycle for well water filtration system.

  • Capable of controlling pump and up to four greensand tanks.

  • Measures and displays flow which can be used to determine that system is working effectively.

  • Water flow ranges between 0-100 GPM (gallons per minute). Typical service flow rate is 75 GPM (@ 3.5 fps).

  • Backwash Cycle:



o First Stage: 8 GPM/Sq Ft o Main Wash: 15 GPM/Sq. Ft o Maximum Backwash Rate: 18 GPM/Sq. Ft o Backwash Flow Rate: 75 GPM o First Stage Flow Rate: 40 GPM o First Stage Duration: 2 minutes o Total Backwash Duration: 10 minutes




  • Quantity of Five (5) units at locations listed.

  • Contractor Requirements



 Must have minimum of five years documented experience in well water filtration systems and satisfactory performance ratings in Federal rating systems.



Installation and Training




  • Includes turnkey installation, integration, programming and training

  • Includes Operator and Maintenance (O&M) Manual complete with schematics, recommended spare parts, and part numbers.

  • Electronic copies of schematics, program data and ladder diagrams must be provided.





Contractor Site Visits




  • Interested contractors are encouraged to see the application prior to bidding on these controllers.

  • Minimum 48 hours’ notice is required and is limited to maximum of two hours per site.

  • Availability for site visits is during work hours of Monday through Friday 08:00 – 15:00.


Attachments/Links
Contact Information
Contracting Office Address
  • KO CONTRACTING DIVISION 332 MINNESOTA STREET SUITE 1500
  • SAINT PAUL , MN 55101-1323
  • USA
Primary Point of Contact
Secondary Point of Contact
History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.