BLDG 854 Repair MV Switch x2

Agency: DEPT OF DEFENSE
State: Michigan
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159569663741522
Posted Date: Apr 9, 2024
Due Date: Apr 17, 2024
Solicitation No: W50S85-24-Q-A015
Source: Members Only
Follow
BLDG 854 Repair MV Switch x2
Active
Contract Opportunity
Notice ID
W50S85-24-Q-A015
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
NGB
Office
W7NF USPFO ACTIVITY MIANG 127
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Updated Published Date: Apr 09, 2024 01:32 pm EDT
  • Original Published Date: Apr 02, 2024 07:51 am EDT
  • Updated Date Offers Due: Apr 17, 2024 02:00 pm EDT
  • Original Date Offers Due: Apr 17, 2024 02:00 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: May 02, 2024
  • Original Inactive Date: May 02, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: J061 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
  • NAICS Code:
    • 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
  • Place of Performance:
    Selfridge ANGB , MI 48045
    USA
Description

Building 854 on Selfridge ANGB has (2) two Vacuum Circuit Breakers that need to be refurbished. This service is to troubleshoot, repair and refurbish two backup MV Vacuum Circuit Breakers. Vacuum Circuit Breaker # (1) one has problems closing. Vacuum Circuit Breaker # (2) two has a burned-out motor.





Contractor shall adhere to standards in accordance with OSHA and NFPA 70E. Provide all necessary equipment, personnel, and materials for testing. Contractor shall work with 127 Civil Engineer office for electrical requirements while removing and installing breakers. At SANGB, contractor shall remove medium voltage vacuum breakers from building 854 and transport them to contractor’s location. Troubleshoot, repair breakers, and provide new parts to restore breaker to functionality. All repairs are in accordance with approved manufacturer recommendations and industry standards and parts. Test breakers at contractor’s location; when ready the contractor shall return breakers to SANGB, install and test breakers in building 854. Prior to acceptance, the Government POC shall observe testing. Provide a signed test report that certifies completion.


Attachments/Links
Contact Information
Contracting Office Address
  • KO FOR MIANG DO NOT DELETE 43200 MAPLE ST BLDG 105
  • SELFRIDGE ANGB , MI 48045-5213
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Apr 2, 2024[Combined Synopsis/Solicitation (Updated)] BLDG 854 Repair MV Switch x2

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >