WANTED TO LEASE BY THE STATE OF CALIFORNIA - SANTA ANA

Agency: State Government of California
State: California
Level of Government: State & Local
Category:
  • 56 - Construction and Building Materials
  • X - Lease or Rental of Facilities
  • Y - Construction of Structures and Facilities
Opps ID: NBD10570615302735189
Posted Date: Oct 30, 2023
Due Date: Dec 31, 2023
Solicitation No: 0000029191
Source: Members Only

Details

Event ID
0000029191

Format/Type:
Sell Event / RFx

Published Date
10/30/2023  8:01AM PDT

Dept:
Department of General Services

Event Version
1

Event End Date:
12/31/2023  6:00PM PST

Description:

WANTED TO LEASE
BY THE STATE OF CALIFORNIA - SANTA ANA
The California Highway Patrol is looking for approx. 5.0 acres of land in the City of Santa Ana, for the future development of a new CHP Santa Ana area field office.

This 20-year lease-purchase project, to be built by a private sector developer, will include the construction of a new CHP Area Office consisting of approximately 40,114 square foot office building with an auto service building, a 750 square foot radio vault building and a 750 square foot property storage building.  Site development includes a 120 ft. high Communication Tower with a total height of 148 ft. to the top of the mast and lightning rod, secured patrol parking, property perimeter CMU wall fence, fuel island with a 12,000-gallon aboveground storage tank, generator and fuel tank, public parking and site utilities.

The building shall be built as a sustainable and energy-efficient building complex that complies with the California Green Building Code and meets the Essential Services Seismic Safety Act of 1986 criteria.  The State will select the best available site for CHPs program needs based on the minimum criteria listed below.  All participants/developers/lessors will competitively bid on the project based on their site submitted.  The developer will control the site.

Land sites submitted must meet the following criteria to be considered:

1) Site characteristics -
a.        The site must be a minimum of five acres pending project program size (consider SWPPP requirement which may require additional acreage).
b.        Land must be free of setbacks, unbuildable easements, set asides and mandatory inclusions e.g., retention ponds.  Areas adjacent to streams or waterways not included in usable acreage. If the site is larger than requirement, is it divisible.
c.        The site buildable area inclusive of parking is desired to be level.  Steep slopes shall not be counted as usable land.  Prefer parcels with single grade for operational efficiencies.  Site should have a width to depth ration of approximately 2:1. Triangular shapes may be acceptable in some instances.  Difficult to develop parcels to be considered on a case-by-case basis.
d.        Railroad crossings or sidings; access; commercial vehicles:  Access to major streets should not be via railroad crossings or sidings.
e.        Require sites near freeway on/off ramps; alternate freeway access; minimal stop signs, traffic barriers, congested routes; no median obstructions; access should avoid shopping centers and schools for safety issues.
f.        Consider adjacent properties which may conflict with programmatic operational needs relative to surrounding community.  Adjacent properties that have multi-story buildings, airports, hospitals, schools and private residences all pose impacts to programmatic considerations and should be avoided.
g.        Site shall be able to accommodate two (2) ingress/egress points.  Site must accommodate Surface Transportation Assistance Act (STAA) vehicles.
h.        Desire public sewer system preferred to septic sewer; ready availability of telephone, cable/satellite, gas and electricity; public water supply preferred to private; non-potable water for irrigation/LEED consideration.

2) Communications Tower interference and line of sight-
a.        Have readily available connectivity for a 148 ft height communications tower.   Height will vary depending on the site selected and based on ¿line of sight¿ requirements.
b.        High voltage power lines adjacent to site impact radio signals and tower must be able to be sited a minimum of 100 ft from any overhead power lines.
c.        Electromagnetic or radio frequency interference- Site should not be near sources of electromagnetic or radio frequency interference to assure proper functioning of computer hardware and to avoid shielding computer rooms.
d.        Long term line of sight - Existing zoning allowing high-rise structures that could interfere with communications line of site (Study required to verify prior to site selection).
e.        Communication Tower and Equipment- Due to sensitive nature of communications equipment, any site is required to file a federal aviation administration (FAA) notice. The FAA notice criteria is defined by CFR Tittle 14 Part 77.9 and the FAA notice criteria tool can be found at: https://oeaaa.faa.gov/oeaaa/external/gisTools/gisAction.jsp?action=showNoNoticeRequiredToolForm.

3) Avoid sources of vibrations and operational disturbance sources- Site should avoid being near sources of vibration (airports, rail lines, heavy trucking, etc.)
a.        Airport- Site shall not be located within a half mile of any security boundary encompassing international, regional, military, or local airports or landing strips.
b.        High Commercial Trucking Areas- In order to minimize the impact of possible uncontrolled heavy vehicle traffic, the proposed site shall not be located in the same complex or adjacent to any existing large consumer shopping center or ¿big box¿ stores. This includes any adjacent unapproved properties which are currently planned for constructing any of the above mentioned. Sites will be reviewed for adjacent properties and their current zoning.
c.        Preference will be given to sites with adjacent properties having compatible use.

4)  Proximity to Public Transportation- Preference will be given to a site with reasonable access (within .25 miles) to public transportation and alternative modes of transportation.

5)  Railway System - site is a minimum of .5 miles from active railway system.

6)  Electrical Power Provider - Site is served by an electrical utility provider with a demonstrated history of providing uninterrupted service, defined as no longer than 36 hours.

7)  Sites that will accommodate State plans, specifications, seismic safety, Americans with Disabilities Act (ADA) and applicable codes (California Building Code & Title 24).

8) Comply with Disabled Veteran Business Enterprise requirements.

The submitter must prove control of the site as either fee title owner or evidence of a sales agreement or option to purchase agreement with the landowner, which details and proves the submitters right to submit the site to the State for further consideration.

The following must be submitted with the land site submittal:

A) Phase I Environmental Report specific to the site submitted.

B) Preliminary Title Report that must at a minimum:
1.        Be provided by a title company authorized to issue policies of title insurance within the State of California.
2.        Contain hyperlinks to all vesting documents and vesting reference documents, exceptions to coverage documents including embedded reference documents, all embedded documents in legal descriptions, maps of record, and map reference documents.
3.        Cover the entire property or as applicable, a majority of the facility property which, at a minimum, includes the proposed project site area, and all bond encumbered areas at the entire site.
4.        Updated Preliminary Reports to be provided if so requested and provide hard copies of all documents.

C) Title Exceptions Map
Contain and depict, at a minimum, the following information:
1.        Address(es) if disclosed in record documents or observed while conducting the survey.
2.        Gross land area of the entire proposed project site area(s) including the land area leading to the point of utility interconnection.
3.        Plot the proposed project site area relative to the overall facility boundary of record.
4.        Plot substantial features or unrecorded encumbrances observed in the process of conducting the survey (in addition to the improvements and    structures, if any) labeling all as practicable.
5.        Plot and label the greater boundaries of the identified property in accordance with the Preliminary Report requirements above.
6.        Plot and label information contained in the Preliminary Report, such as, but not limited to, the Preliminary Reports legal description, propertys vesting deeds, title exceptions, encumbrances in recorded maps, and any other discovered or identified encumbrances whether of county record or unrecorded.
7.        Plot and label all bond encumbrances, if any, whether of county record or unrecorded.
8.        When preparing the Title Exceptions Map, include the corresponding Preliminary Report, its report number and date, and Assessors Parcel Number(s) covered.
9.        Either be to scale, with scale stated, or have geometric relationship to a current Aerial Map if used.
10.        Stamped and dated by a Land Surveyor licensed in the State of California and wet signed; and
11.        Provide updated Title Exceptions Maps.

D) Access & Utility Map:
Provide an access and utility map of the identified property that reflects the following:
1.        Plot and label the identified property relative to overall adjacent properties and surrounding features.
2.        Locate the proposed project site within the identified property.
3.        Identify and label access from the proposed project site to the nearest publicly dedicated right of way.
4.        Identify and label all project utilities (e.g., water, gas, sewer, electric, communications, etc.) and utility travel routes from the proposed project site to points of connection in public utility easements or publicly dedicated right of way.

E) Unrecorded rights:
Identifying unrecorded rights is required as part of the real estate title due diligence analysis in support of the facilitys project design authority. Sometimes conditions exist in real property that one assumes are recorded legal uses (e.g., roadways, irrigation/flood control facilities, ditches, encroachments, or utility lines). However, a visually identified or known periodic use may not appear in the    propertys preliminary report.

Some examples of ¿unrecorded rights¿ that encumber or may otherwise affect the          property interests of the greater property are contracts, leases, licenses, permits, agreements, and memoranda of understanding with public or private entities or persons that affect the use and/or occupancy of the greater property. Generally, any potentially enforceable right another entity or person may claim that allows them to use, occupy, or cross the greater property.

PERSONS AUTHORIZED TO REPRESENT SUCH PROPERTIES MUST RESPOND TO CONTACT PERSON BY RESPONSE DATE WITH ADDRESS, MAP & PROJECT NUMBER BY EMAIL OR IN WRITING TO: RESD, 707 Third Street, 5th Floor, P.O. Box 989052, West Sacramento, CA 95798-9052.

Project # - 3060
City - Santa Ana
County - Orange
Agency - California Highway Patrol
Type of Space - land for a lease-purchase build-to-suit
Parking Spaces - 113 for State cars and 41 for public parking
Boundaries:
North:  Border of Los Angeles (LA) and Orange (OC) County Line
East:  Border of Orange and Riverside County Line
South:   Pacific Ocean, North of Laguna Beach to Trabuco Canyon
West:   East border of Santa Ana River to North of Brea City Limit

Contact - Kerry Zadel
Phone - 916.376.1617
Email Address - Kerry.Zadel@dgs.ca.gov
Fax - 916.375.4173 (Hard copy must follow if document(s) are sent by Email)
Response Date - December 31, 2023

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >