King and Queen County School Well System Improvement
- Status: Open
- Time Left:13 days, 20 hours
- Closing:7/6/23 5:00 PM
- Issued:6/22/23 4:27 PM
- Last Updated:
- Buyer:Tina Ammons
-
tammons@kingandqueenco.net - 804-785-5975
QQ-19180
-
King and Queen County School Well System Improvement
- Status: Open
- Time Left:13 days, 20 hours
- Closing:7/6/23 5:00 PM
- Issued:6/22/23 4:27 PM
- Last Updated:
- Buyer:Tina Ammons
-
tammons@kingandqueenco.net - 804-785-5975
Actions
- Issued By:King and Queen County
- Opportunity Type:Quick Quote
- Category:Construction
-
Work Location:King and Queen County Central High School
17024 The Trail
King and Queen Court House, VA 23085
- Website:
-
Summary:Existing King & Queen County High School waterworks system is over 50 years old and requires modernization to provide increased water capacity and reliability for school and adjacent chiller system. Design/Build contractor (Contractor) will provide and submit design drawings and submittal necessary for Virginia Department of Health Office of Drinking Water (ODW) approval. A new well is currently being drilled and new well data can be requested from the county administrator’s office. Once ODW approval is received, the Contractor will complete scope of work described below; which shall be completed by July 28, 2023.
The improvements to the water system shall include:
o Take 5,000 gallon hydropneumatic tank offline
o Create 5,000 gallon of unpressurized ground storage to increase effective storage and allow for trucked water if well is out of service.
Tank shall have
• level sensor rods
• Fire Department Connection
• Access hatch or viewing port on top of tank.
• Inlet & Outlet properly sized for well and school flows
Clean and disinfect interior of tank
Field paint exterior of tank
o Install duplex booster system capable of 50 gpm @ 55 psi.
o Install new 4”well pump end and associated motor capable of 40 gpm @ head to be determined (contact the county administrator’s office for drilling records)
o Install pipe and power line between well and existing pump house.
o Install new wall/ceiling mount heater.
o Clean and paint existing block building.
o Clear building drain and dig small swale as necessary.
o Install two (2) 119 gallon bladder tanks for pressurized storage
To ensure single point of contact, the Contractor shall have on staff professional engineers registered in the Commonwealth of Virginia. Furthermore the Contractor shall self perform all mechanical and electrical work as necessary to complete the required scope of work. Upon request contractor shall provide at least 5 examples of similarly scoped design/build projects performed in Virginia. To contact the county administrator’s office, call (804) 785-5975 or email vseay@kingandqueenco.net or buildingofficial@kingandqueenco.net.
Follow B2B ActivityUnfollow B2B ActivityAdd B2B Posting
There are no B2B messages to display
- I1_1. Existing King & Queen County High School waterworks system is over 50 years old and requires modernization to provide increased water capacity and reliability for school and adjacent chiller system. Design/Build contractor (Contractor) will provide and submit design drawings and submittal necessary for Virginia Department of Health Office of Drinking Water (ODW) approval. A new well is currently being drilled and new well data can be requested from the county administrator’s office. Once ODW approval is received, the Contractor will complete scope of work described below; which shall be completed by July 28, 2023. The improvements to the water system shall include: o Take 5,000 gallon hydropneumatic tank offline o Create 5,000 gallon of unpressurized ground storage to increase effective storage and allow for trucked water if well is out of service. Tank shall have • level sensor rods • Fire Department Connection • Access hatch or viewing port on top of tank. • Inlet & Outlet properly sized for well and school flows Clean and disinfect interior of tank Field paint exterior of tank o Install duplex booster system capable of 50 gpm @ 55 psi. o Install new 4”well pump end and associated motor capable of 40 gpm @ head to be determined (contact the county administrator’s office for drilling records) o Install pipe and power line between well and existing pump house. o Install new wall/ceiling mount heater. o Clean and paint existing block building. o Clear building drain and dig small swale as necessary. o Install two (2) 119 gallon bladder tanks for pressurized storage
- NIGP Code:
- Quantity: 1.00000 each
- Delivery Date:
B2B Follow
×
Enter Email Address:
CloseSubmit
B2B Unfollow
×
Enter Email Address:
CloseSubmit
Add B2B Posting
×
Contact Name:
Company Name:
Email Address:
Phone Number:
SWaM Certifications:
Micro Business
Small Business
Minority Owned Business
Women Owned Business
Service Disabled Veteran Owned
Employment Service Org
Micro Business
Small Business
Minority Owned Business
Women Owned Business
Service Disabled Veteran Owned
Employment Service Org
Message:
CloseSubmit
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.